Doppler Blood Flow Detector

Content Overview
The Blood Flow Detector is primarily used during surgery to provide: navigational assistance, navigation replacement without external systems, and elimination of guesswork based on experience. It enables precise intraoperative vessel localization, replacing tactile sensation and optimistic estimation. As an A-mode ultrasound device, it utilizes the Doppler effect principle to perform real-time monitoring of blood flow within vessels.
1. Host Features:
1. LCD large screen for real-time switching between dual-direction waveforms or 7 monitoring parameters
2. Built-in high-speed printer for instant printing of flow graphs and monitoring data
3. The host can store 30 sets of waveforms and measurement data.
4. Unique probe freeze key instantly reads waveforms and monitoring data during measurement.
5. Compatible with various reusable intraoperative probes of different frequencies
6 Can independently assess arterial and venous conditions.
7.Configure probe direction, mode, frequency, language, waveform, data, and more.
8. Includes rechargeable battery and power adapter
II. Smartdop 45 System Clinical Detection Parameters:
S: Systolic blood flow velocity (cm/s)
MN: Mean Doppler Shift (cm/s)
D: Diastolic Flow Velocity (cm/s)
RP: Resistance Percentage | RP = (S-D)/S | RP = 1 (if waveform is below baseline)
PI: Pulsatility Index (Peak-to-Peak) MN PI ≤ 99.99
SD: S/D ratio, SD = S/D
HR: Heart Rate
3. Smartdop 45 Parameters
Power: Ni-Mh rechargeable battery or AC/DC adapter
230VAC, 50Hz
Output: 12VDC, 580mA
Power Consumption: DC 12 V, 500 mA
Charging: approximately 3 hours, AC
Battery life at full charge: 5 hours
Auto-off: No signal for 5 minutes, Freeze: 10 minutes, Others: 15 minutes
Mode Settings: Storage, Waveform, Direction, Time Scale, Other
Stored waveforms: 30 sets
LCD Display: 128 x 64 dots, STN LCD
Bidirectional blood flow velocity waveform
Data (Systolic, Diastolic, and Mean Flow Velocity, Pulsatility Index, Resistance Index, Heart Rate, Systolic/Diastolic Flow Velocity Ratio)
Heart Rate: 30 to 300BPM (Accuracy ±5%)
Battery Level and Low Battery Indicator
Printer:
Paper: Resolution: Print Speed: | Width 58 mm × Length 25 m / With shaft hole, thermal 256 point/line 25 mm/s |
Speaker output: 250 mW or more
Dimensions: Main unit 115(W) x 210 (D) x 60 (H) mm (probe stand not included)
Probe: 20 (Diam.) x 105 (L) mm
Weight: Approx. 560 g (includes 1 probes and battery)
IV. Smartdop 45 Clinical Indications
1 Intraoperative Applications: Aneurysm Clipping, Moyamoya Disease (Bypass Surgery), Skull Base Tumor Vascular Exploration, Varicocelectomy, Endarterectomy, Peripheral Vascular Research, Arterial Function Assessment.
2: Suitable for clinical examinations, pre- and post-operative assessments of vascular anastomosis, measurement of peak and mean blood flow velocity, and perforator flap exploration.